How to use: Choose your cartridge, or enter its output and recommended load from its specifications. Then enter your phono stage's gain and its input capacitance or load setting, from its manual, and your cable's capacitance and length.
Fills in the cartridge's figures from its maker's own published specifications.
Moving magnet (MM) or moving iron
Moving coil (MC)
At 5 cm/s, 1 kHz, as most specifications give it
From its specifications: often 35–40 dB on MM inputs, 55–65 dB on MC inputs
The cartridge's coil, from its specifications: these give the predicted response graph.
The maker's figure for everything the cartridge sees: the phono stage's input, the cable and the tonearm's wiring.
From its specifications; often 100 pF, some adjustable
Usually 47 kΩ; some phono stages offer other settings
From spec (pF/m × length)
Measured total
Typically 50–150 pF/m; add 50–100 pF for the tonearm's wiring

Follow Passolio for the next tool: Instagram · Facebook · YouTube

Know someone who'd find it useful? Share this tool

Gain

A cartridge's output is tiny: a few millivolts for a moving magnet, a few tenths of a millivolt for most moving coils. The phono stage raises it to the level of other sources, a few hundred millivolts. Too little gain and you turn the volume right up and hear more hiss and hum; too much and loud passages can overload the stage. Each 6 dB of gain doubles the level.

Capacitance, for moving magnet cartridges

A moving magnet cartridge's coil and the capacitance after it, the phono stage's input and the cable, form a resonance near the top of the audible range. Its maker gives the range of total capacitance that keeps the treble as intended. Too much capacitance dulls the treble or adds a peak below it; long or high-capacitance cables are the usual cause. Too little is rarely a problem; some phono stages let you add capacitance.

Measuring your cable's capacitance

You need a multimeter with a capacitance range; many inexpensive ones have one, and its smallest range (often 2 nF) reads to about 1 pF. Unplug the turntable's cable from the phono stage or amplifier, and carefully unclip the four leads from the cartridge pins (or take off the headshell), so that nothing is connected at either end. Set the meter to that range and use its zero or REL (relative) button with its leads apart, so their own capacitance isn't counted. Then hold one lead on the centre pin and the other on the outer shell of one phono plug, and read the capacitance. Do both channels; they should be close.

That reading is the cable and the tonearm's wiring together, which is what the cartridge sees: choose Measured total above and enter it. If your turntable has a detachable cable, you can also measure the cable on its own, unplugged at both ends, to see how much of the total it accounts for.

Without a meter, use the cable maker's figure in pF per metre, and allow 50–100 pF more for the tonearm's wiring. The phono stage's input capacitance is in its manual or specifications.

Resistance, for moving coil cartridges

A note on words first. The load is the phono stage's input impedance, in ohms. The lower the impedance, the heavier the load, because the cartridge has to drive more current through it: 100 Ω loads a cartridge far more heavily than 47 kΩ.

A moving coil cartridge's coil has a very low internal impedance, a few ohms to a few tens of ohms, and is too small to be braked noticeably by the load, so neither the capacitance nor the load resistance shapes the audible response. The load does three things. First, it sets how much of the coil's signal reaches the phono stage: the internal impedance and the load share the signal like a voltage divider, so the more ohms the load has compared with the internal impedance, the less is lost. At ten times the internal impedance about 0.8 dB is lost; at five times, 1.6 dB; with the two equal, 6 dB. The result above shows the loss for your settings.

Second, a lower setting tames a peak far above hearing, often hundreds of kHz or more, where the coil's small inductance resonates with the cable's capacitance. Some phono stages are sensitive to energy up there and can sound harder for it; with those, a lower setting can genuinely sound cleaner. Third, with a step-up transformer, the load also shapes the transformer's own treble response, often audibly, so follow the transformer maker's advice.

That is why the common starting point is about ten times the cartridge's internal impedance: little level is lost, and the ultrasonic peak is still tamed. Never go below the maker's minimum. If you compare settings by ear, match the levels first: the louder one nearly always sounds more open and detailed. Use the phono stage's gain, not the load, to set the level.